Generac PWRcell 2

Generac states 9 kWh (PWRcell 2 M3, United States) to 18 kWh (PWRcell 2 M6, United States) usable energy.

Generac states 5.2 kW (PWRcell 2 M3, United States) to 10.5 kW (PWRcell 2 M6, United States) continuous power.

Warranty terms: 10 years; warranted throughput: 7.56 MWh (per module); capacity at warranty end: 70%.

Named configurations include PWRcell 2 M3, PWRcell 2 M4, PWRcell 2 M5 and PWRcell 2 M6.

Brand: Generac

Published figures

No figures have been collected for units per system.

Generac PWRcell 2: 24 published figures
FigureValuePublisherSource
Usable energy 18 kWh Manufacturer Not yet checked Spec sheet, at p.5 / BATTERY CONFIGURATIONS, retrieved Sep 23, 2026
Usable energy, Generac PWRcell 2 M3 (9 kWh), Generac PWRcell 2 M3 9 kWh Manufacturer Not yet checked Spec sheet, at p.2 PWRcell 2 System Specifications / Usable Energy, retrieved Sep 23, 2026
Usable energy, Generac PWRcell 2 M4 (12 kWh), Generac PWRcell 2 M4 12 kWh Manufacturer Not yet checked Spec sheet, at p.2 PWRcell 2 System Specifications / Usable Energy, retrieved Sep 23, 2026
Usable energy, Generac PWRcell 2 M5 (15 kWh), Generac PWRcell 2 M5 15 kWh Manufacturer Not yet checked Spec sheet, at p.2 PWRcell 2 System Specifications / Usable Energy, retrieved Sep 23, 2026
Usable energy, Generac PWRcell 2 M6 (18 kWh), Generac PWRcell 2 M6 18 kWh Manufacturer Not yet checked Spec sheet, at p.2 PWRcell 2 System Specifications / Usable Energy, retrieved Sep 23, 2026
Continuous power 10.5 kW Manufacturer Not yet checked Spec sheet, at p.2 / PERFORMANCE, retrieved Sep 23, 2026
Continuous power, Generac PWRcell 2 M3 (9 kWh), Generac PWRcell 2 M3 5.2 kW Manufacturer Not yet checked Spec sheet, at p.2 PWRcell 2 System Specifications / Max. Continuous Power, retrieved Sep 23, 2026
Continuous power, Generac PWRcell 2 M4 (12 kWh), Generac PWRcell 2 M4 7 kW Manufacturer Not yet checked Spec sheet, at p.2 PWRcell 2 System Specifications / Max. Continuous Power, retrieved Sep 23, 2026
Continuous power, Generac PWRcell 2 M5 (15 kWh), Generac PWRcell 2 M5 8.7 kW Manufacturer Not yet checked Spec sheet, at p.2 PWRcell 2 System Specifications / Max. Continuous Power, retrieved Sep 23, 2026
Continuous power, Generac PWRcell 2 M6 (18 kWh), Generac PWRcell 2 M6 10.5 kW Manufacturer Not yet checked Spec sheet, at p.2 PWRcell 2 System Specifications / Max. Continuous Power, retrieved Sep 23, 2026
Peak power (AC) 11.5 kW Manufacturer Not yet checked Spec sheet, at p.7 PWRcell 2 Inverter / AC Output, retrieved Sep 23, 2026
Motor start (LRA), Generac PWRcell 2 M3 (9 kWh), Generac PWRcell 2 M3 65 A Manufacturer Not yet checked Spec sheet, at p.2 PWRcell 2 System Specifications / Max. AC Start Capacity, retrieved Sep 23, 2026
Motor start (LRA), Generac PWRcell 2 M4 (12 kWh), Generac PWRcell 2 M4 87 A Manufacturer Not yet checked Spec sheet, at p.2 PWRcell 2 System Specifications / Max. AC Start Capacity, retrieved Sep 23, 2026
Motor start (LRA), Generac PWRcell 2 M5 (15 kWh), Generac PWRcell 2 M5 108 A Manufacturer Not yet checked Spec sheet, at p.2 PWRcell 2 System Specifications / Max. AC Start Capacity, retrieved Sep 23, 2026
Motor start (LRA), Generac PWRcell 2 M6 (18 kWh), Generac PWRcell 2 M6 130 A Manufacturer Not yet checked Spec sheet, at p.2 PWRcell 2 System Specifications / Max. AC Start Capacity, retrieved Sep 23, 2026
Round-trip efficiency 88% Manufacturer Not yet checked Spec sheet, at p.2 / PERFORMANCE, retrieved Sep 23, 2026
Lowest operating temperature (discharging) −20°C Manufacturer Not yet checked Spec sheet, at p.2 / ENVIRONMENTAL, retrieved Sep 23, 2026
Lowest operating temperature (charging) −5°C Manufacturer Not yet checked Spec sheet, at p.2 / ENVIRONMENTAL, retrieved Sep 23, 2026
Highest operating temperature (discharging) 50°C Manufacturer Not yet checked Spec sheet, at p.2 / ENVIRONMENTAL, retrieved Sep 23, 2026
Highest operating temperature (charging) 50°C Manufacturer Not yet checked Spec sheet, at p.2 / ENVIRONMENTAL, retrieved Sep 23, 2026
Weight, Generac PWRcell 2 M3 (9 kWh), Generac PWRcell 2 M3 126.1 kg Manufacturer Not yet checked Spec sheet, at p.5 Battery Cabinet Specifications / Total Weight of Installed Unit, retrieved Sep 23, 2026
Weight, Generac PWRcell 2 M4 (12 kWh), Generac PWRcell 2 M4 151 kg Manufacturer Not yet checked Spec sheet, at p.5 Battery Cabinet Specifications / Total Weight of Installed Unit, retrieved Sep 23, 2026
Weight, Generac PWRcell 2 M5 (15 kWh), Generac PWRcell 2 M5 176 kg Manufacturer Not yet checked Spec sheet, at p.5 Battery Cabinet Specifications / Total Weight of Installed Unit, retrieved Sep 23, 2026
Weight, Generac PWRcell 2 M6 (18 kWh), Generac PWRcell 2 M6 200.9 kg Manufacturer Not yet checked Spec sheet, at p.5 Battery Cabinet Specifications / Total Weight of Installed Unit, retrieved Sep 23, 2026

See it on the home battery chart

Stated temperature limits

Stated charging range: 23°F (−5°C) to 122°F (50°C).

Spec sheet, at p.2 / ENVIRONMENTAL, retrieved Sep 23, 2026 Not yet checked

Stated discharging range: −4°F (−20°C) to 122°F (50°C).

Spec sheet, at p.2 / ENVIRONMENTAL, retrieved Sep 23, 2026 Not yet checked

Compare temperature limits.

After you enter a ZIP code, day counts describe outdoor air at the nearest station. A garage or indoor unit sees different air from the station. Output reductions inside the stated range are not counted.

Battery’s stated motor-start current: 65 A for the Generac PWRcell 2 M3, 87 A for the Generac PWRcell 2 M4, 108 A for the Generac PWRcell 2 M5, 130 A for the Generac PWRcell 2 M6 (LRA means locked-rotor amps, a motor’s starting current). Compare starting current.

Warranty terms

Generac PWRcell 2 warranty terms
TermFigureDocument
Warranty10 yearsWarranty, at p.1 / Warranty Coverage table, retrieved Sep 23, 2026
Warranted throughputper module: 7.56 MWhWarranty, at p.1 / Warranty Coverage table, retrieved Sep 23, 2026
Capacity at warranty end70%Warranty, at p.1 / Warranty Coverage table, retrieved Sep 23, 2026
Warranty, at p.1 / Warranty Coverage table, retrieved Sep 23, 2026 Not yet checked

Compare warranties.

Features the manufacturer states

Generac PWRcell 2: stated features
FeatureStatedSource
Chemistry NMC Not yet checked Spec sheet, at p.6 / 3.0 kWh DCB Battery Module > MECHANICAL, retrieved Sep 23, 2026
Coupling AC Not yet checked Spec sheet, at p.1, retrieved Sep 23, 2026
Whole-home backup Yes Not yet checked Spec sheet, at p.2 Smart Disconnect Switch panel, retrieved Sep 23, 2026
Backup Whole and partial home backup up to 200 A via Smart Disconnect Switch, automatic transfer < 50 ms, generator integration up to 28 kW Not yet checked Spec sheet, at p.2 Smart Disconnect Switch panel, retrieved Sep 23, 2026
Built-in inverter No Not yet checked Spec sheet, at p.7 PWRcell 2 Inverter, retrieved Sep 23, 2026
Compatible inverters Generac PWRmicro and Enphase IQ8 (AC-coupled PV) Not yet checked Spec sheet, at p.2 System Specifications, retrieved Sep 23, 2026
Enclosure rating NEMA 3R Not yet checked Spec sheet, at p.2 Environmental, retrieved Sep 23, 2026
Nominal battery voltage 46.8 V Not yet checked Spec sheet, at p.6 DCB Battery Module / Nominal Voltage, retrieved Sep 23, 2026
Grid voltage 120/240 split phase V AC Not yet checked Spec sheet, at p.7 PWRcell 2 Inverter / Nominal Grid Voltage, retrieved Sep 23, 2026
Dimensions 271 x 582 x 1777 (D x W x H) mm Not yet checked Spec sheet, at p.5 Battery Cabinet Specifications / Dimensions, retrieved Sep 23, 2026

Configurations

Configurations named by the figures

  • PWRcell 2 M3
  • PWRcell 2 M4
  • PWRcell 2 M5
  • PWRcell 2 M6

Government and program lists

This product is on none of the lists this site reads.

Installs

No install count this site publishes covers this product.

Recalls and safety notices

No notice in the recall sources this site reads is matched to this product. That is not a safety finding. See every recall notice.

  • UL 9540 listed: Yes
    Spec sheet, at p.2 Compliance, retrieved Sep 23, 2026 Not yet checked
  • UL 9540A tested: Yes
    Spec sheet, at p.2 Compliance, retrieved Sep 23, 2026 Not yet checked

The maker states the listing or test. The listing body's records have not been checked.

Backup hours from your load

Appliance nameplate maximums

The stated usable energy divided by your load gives hours, starting with a full battery.

The spec sheet states its usable energy at 25°C.

Spec sheet, at p.2 PWRcell 2 System Specifications / Usable Energy, retrieved Sep 23, 2026 Not yet checked

Backup hours follow the California Air Resources Board’s Zero Emissions Residential Backup Power Tool. Appliance figures come from the US Department of Energy’s Estimating Appliance and Home Electronic Energy Use (2012).

  • The appliance figures are nameplate maximums. Average demand changes as appliances cycle and their settings change.
  • A load above the stated continuous power gets no figure.
  • Motor starts use three times the largest selected motor’s watts, plus the other loads. This estimate is checked against stated peak power when available. Other loads are counted at their running watts.
  • Inverter and battery losses are not counted. A field study of household backup power explains the gap.
  • Solar recharge, reserves, and temperature changes are outside the calculation.