Home Battery List

GoodWe Lynx Home U

GoodWe states 5 kWh usable energy (GoodWe Lynx Home U G3 (LXU 5.0-30)) and 5.12 kWh nominal energy (GoodWe Lynx Home U G3 (LXU 5.0-30)).

GoodWe states 4.95 kW continuous power (GoodWe Lynx Home U G3 (LXU 5.0-30)).

Warranty terms: 10 years (GoodWe Lynx Home U G3 (LX U 5.0-30), Europe); warranted throughput: 14.3 MWh (GoodWe Lynx Home U G3 (LX U 5.0-30), Europe); warranted cycles: 6,000 cycles (GoodWe Lynx Home U G3 (LXU 5.0-30)); capacity at warranty end: 70% (GoodWe Lynx Home U G3 (LX U 5.0-30), Europe).

Brand: GoodWe

Published figures

No figures have been collected for motor-start current and units per system.

GoodWe Lynx Home U: 10 published figures
FigureValuePublisherSource
Usable energy, GoodWe Lynx Home U G3 (LXU 5.0-30) 5 kWh Manufacturer Not yet checked Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025
Nominal energy, GoodWe Lynx Home U G3 (LXU 5.0-30) 5.12 kWh Manufacturer Not yet checked Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025
Continuous power, GoodWe Lynx Home U G3 (LXU 5.0-30) 4.95 kW Manufacturer Not yet checked Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025
Round-trip efficiency, GoodWe Lynx Home U G3 (LXU 5.0-30) 96% Manufacturer Not yet checked Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025
Lowest operating temperature, GoodWe Lynx Home U G3 (LXU 5.0-30) (discharging) −20°C Manufacturer Not yet checked Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025
Lowest operating temperature, GoodWe Lynx Home U G3 (LXU 5.0-30) (ambient) 0°C Manufacturer Not yet checked Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025 page cited, no quote
Lowest operating temperature, GoodWe Lynx Home U G3 (LXU 5.0-30) (charging) 0°C Manufacturer Not yet checked Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025
Highest operating temperature, GoodWe Lynx Home U G3 (LXU 5.0-30) (ambient) 40°C Manufacturer Not yet checked Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025 page cited, no quote
Highest operating temperature, GoodWe Lynx Home U G3 (LXU 5.0-30) (charging) 55°C Manufacturer Not yet checked Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025
Highest operating temperature, GoodWe Lynx Home U G3 (LXU 5.0-30) (discharging) 55°C Manufacturer Not yet checked Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025

See it on the home battery chart

Usable and nominal energy

Nominal energy is the stated total stored energy. Usable energy is the stated amount available to draw.

GoodWe Lynx Home U G3 (LXU 5.0-30): GoodWe Lynx Home U states 5 kWh usable and 5.12 kWh nominal energy (97% usable).

Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025 Not yet checked

Compare usable and nominal energy.

Stated temperature limits

Stated operating range: 32°F (0°C) to 104°F (40°C), GoodWe Lynx Home U G3 (LXU 5.0-30).

Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025 page cited, no quote

Stated charging range: 32°F (0°C) to 131°F (55°C), GoodWe Lynx Home U G3 (LXU 5.0-30).

Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025 Not yet checked

Stated discharging range: −4°F (−20°C) to 131°F (55°C), GoodWe Lynx Home U G3 (LXU 5.0-30).

Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025 Not yet checked

Compare temperature limits.

After you enter a ZIP code, day counts describe outdoor air at the nearest station. A garage or indoor unit sees different air from the station. Output reductions inside the stated range are not counted.

Warranty terms

GoodWe Lynx Home U warranty terms
TermFigureDocument
Warranty, EuropeGoodWe Lynx Home U G3 (LX U 5.0-30): 10 yearsWarranty, at p1, OVERVIEW item 1, retrieved Sep 23, 2026, dated Jan 1, 2026
Warranted throughput, EuropeGoodWe Lynx Home U G3 (LX U 5.0-30): 14.3 MWhWarranty, at p1, performance table, retrieved Sep 23, 2026, dated Jan 1, 2026
Warranted cyclesGoodWe Lynx Home U G3 (LXU 5.0-30): 6,000 cyclesSpec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025
Capacity at warranty end, EuropeGoodWe Lynx Home U G3 (LX U 5.0-30): 70%Warranty, at p1, OVERVIEW item 2, retrieved Sep 23, 2026, dated Jan 1, 2026
Warranty, at p1, OVERVIEW item 1, p1, performance table, p1, OVERVIEW item 2, retrieved Sep 23, 2026, dated Jan 1, 2026 Not yet checked
Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025 Not yet checked

The stated 14.3 MWh equals 2,860 full cycles of its 5 kWh usable energy, GoodWe Lynx Home U G3 (LXU 5.0-30).

Compare warranties.

Features the manufacturer states

Configuration: GoodWe Lynx Home U G3 (LXU 5.0-30).

GoodWe Lynx Home U: stated features
FeatureStatedSource
Chemistry LFP Not yet checked Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025

Government and program lists

This product is on none of the lists this site reads.

Installs

No install count this site publishes covers this product.

Recalls and safety notices

No notice in the recall sources this site reads is matched to this product. That is not a safety finding. See every recall notice.

Backup hours from your load

Appliance nameplate maximums

The stated usable energy divided by your load gives hours, starting with a full battery.

The spec sheet states its usable energy at 25°C.

Spec sheet, at p2, Technical Data, retrieved Sep 23, 2026, dated Jul 2, 2025 Not yet checked

Backup hours follow the California Air Resources Board’s Zero Emissions Residential Backup Power Tool. Appliance figures come from the US Department of Energy’s Estimating Appliance and Home Electronic Energy Use (2012).

  • The appliance figures are nameplate maximums. Average demand changes as appliances cycle and their settings change.
  • A load above the stated continuous power gets no figure.
  • Motor starts use three times the largest selected motor’s watts, plus the other loads. This estimate is checked against stated peak power when available. Other loads are counted at their running watts.
  • Inverter and battery losses are not counted. A field study of household backup power explains the gap.
  • Solar recharge, reserves, and temperature changes are outside the calculation.

Download this battery’s figures as JSON