Home Battery List

LG RESU16H Prime

LG Energy Solution states 16 kWh usable energy (United States).

LG Energy Solution states 7 kW continuous power (United States, DC).

Warranty terms: 5 years (Europe, minimum coverage if registration or internet connection is missing); 10 years (Europe, requires internet connection and RESU Monitor registration); 10 years (United States); warranted throughput: 54 MWh (Europe); warranted throughput: 54 MWh (United States); capacity at warranty end: 70% (United States); capacity at warranty end: 70% (Europe).

Brand: LG Energy Solution

Published figures

No figures have been collected for motor-start current.

LG RESU16H Prime: 12 published figures
FigureValuePublisherSource
Usable energy 16 kWh Manufacturer Checked against the document Spec sheet, at p.2 / Electrical Characteristics, retrieved Sep 25, 2026Usable Energy1) 16.0 kWh @77°F (25°C)
Spec sheet, at p2, Electrical Characteristics, retrieved Sep 23, 2026
Continuous power (DC) 7 kW Manufacturer Checked against the document Spec sheet, at p.2 / Electrical Characteristics, retrieved Sep 25, 2026Max. Charge/Discharge Power 7 kW
Spec sheet, at p2, Electrical Characteristics, retrieved Sep 23, 2026
Peak power (DC, discharging, for 10 sec.) 11 kW Manufacturer Checked and corrected against the document Spec sheet, at p.2 / Electrical Characteristics, retrieved Sep 25, 2026Peak Power (only discharging)2) 11 kW for 10 sec.
Spec sheet, at p2, Electrical Characteristics, retrieved Sep 23, 2026
Round-trip efficiency, United States 90.3% Manufacturer Not yet checked Warranty, at p.8 / Attachment 1, retrieved Sep 25, 2026, dated Dec 13, 2023
Round-trip efficiency, Europe 90.3% Manufacturer Not yet checked Warranty, at p17, Attachment 1, retrieved Sep 23, 2026, dated Dec 13, 2023
Units per system 2 units Manufacturer Checked against the document Spec sheet, at p.2 / Electrical Characteristics, retrieved Sep 25, 2026Scalability (Total Energy, Max. Charge/Discharge Power) Max. 2 in parallel
Largest stack 32 kWh Manufacturer Checked against the document Spec sheet, at p.2 / Electrical Characteristics, retrieved Sep 25, 2026Max. 2 in parallel (32.0 kWh @77°F (25°C), 14kW)
Lowest operating temperature (discharging) −20°C Manufacturer Checked against the document Spec sheet, at p.2 / Operating Conditions, retrieved Sep 25, 2026Operating Temperature Charge 14 ~ 122°F (-10 ~ 50°C) Discharge -4 ~ 122°F (-20 ~ 50°C)
Spec sheet, at p2, Operating Conditions, retrieved Sep 23, 2026
Lowest operating temperature (charging) −10°C Manufacturer Checked against the document Spec sheet, at p.2 / Operating Conditions, retrieved Sep 25, 2026Operating Temperature Charge 14 ~ 122°F (-10 ~ 50°C) Discharge -4 ~ 122°F (-20 ~ 50°C)
Spec sheet, at p2, Operating Conditions, retrieved Sep 23, 2026
Highest operating temperature (charging) 50°C Manufacturer Checked against the document Spec sheet, at p.2 / Operating Conditions, retrieved Sep 25, 2026Operating Temperature Charge 14 ~ 122°F (-10 ~ 50°C) Discharge -4 ~ 122°F (-20 ~ 50°C)
Spec sheet, at p2, Operating Conditions, retrieved Sep 23, 2026
Highest operating temperature (discharging) 50°C Manufacturer Checked against the document Spec sheet, at p.2 / Operating Conditions, retrieved Sep 25, 2026Operating Temperature Charge 14 ~ 122°F (-10 ~ 50°C) Discharge -4 ~ 122°F (-20 ~ 50°C)
Spec sheet, at p2, Operating Conditions, retrieved Sep 23, 2026
Weight 159 kg Manufacturer Checked against the document Spec sheet, at p.3 / Mechanical Characteristics, retrieved Sep 25, 2026Weight 351 lb (159 kg)

See it on the home battery chart

Stated stack range

One unit: 16 kWh usable. Largest stated stack: 32 kWh (energy basis not stated) (2 units).

Spec sheet, at p.2 / Electrical Characteristics, retrieved Sep 25, 2026Usable Energy1) 16.0 kWh @77°F (25°C), Max. 2 in parallel (32.0 kWh @77°F (25°C), 14kW), Scalability (Total Energy, Max. Charge/Discharge Power) Max. 2 in parallel
Spec sheet, at p2, Electrical Characteristics, retrieved Sep 23, 2026 Not yet checked

Compare stated stack ranges.

Stated temperature limits

Stated charging range: 14°F (−10°C) to 122°F (50°C).

Spec sheet, at p.2 / Operating Conditions, retrieved Sep 25, 2026Operating Temperature Charge 14 ~ 122°F (-10 ~ 50°C) Discharge -4 ~ 122°F (-20 ~ 50°C)
Spec sheet, at p2, Operating Conditions, retrieved Sep 23, 2026 Not yet checked

Stated discharging range: −4°F (−20°C) to 122°F (50°C).

Spec sheet, at p.2 / Operating Conditions, retrieved Sep 25, 2026Operating Temperature Charge 14 ~ 122°F (-10 ~ 50°C) Discharge -4 ~ 122°F (-20 ~ 50°C)
Spec sheet, at p2, Operating Conditions, retrieved Sep 23, 2026 Not yet checked

Compare temperature limits.

After you enter a ZIP code, day counts describe outdoor air at the nearest station. A garage or indoor unit sees different air from the station. Output reductions inside the stated range are not counted.

Warranty terms

LG RESU16H Prime warranty terms
TermFigureDocument
Warranty, Europe5 years (minimum coverage if registration or internet connection is missing)Warranty, at p4, Art. 7, retrieved Sep 23, 2026, dated Dec 13, 2023
Warranty, Europe10 years (requires internet connection and RESU Monitor registration)Warranty, at p2, Art. 3, retrieved Sep 23, 2026, dated Dec 13, 2023
Warranty, United States10 yearsWarranty, at p.2 / s.3 Product Warranty, retrieved Sep 25, 2026, dated Dec 13, 2023
Warranted throughput, Europe54 MWhWarranty, at p2, Art. 4.1 table, retrieved Sep 23, 2026, dated Dec 13, 2023
Warranted throughput, United States54 MWhWarranty, at p.2 / s.4.1 table, retrieved Sep 25, 2026, dated Dec 13, 2023
Capacity at warranty end, United States70%Warranty, at p.2 / s.4.1, retrieved Sep 25, 2026, dated Dec 13, 2023
Capacity at warranty end, Europe70%Warranty, at p2, Art. 4.1, retrieved Sep 23, 2026, dated Dec 13, 2023
Warranty, at p4, Art. 7, p2, Art. 3, p2, Art. 4.1 table, retrieved Sep 23, 2026, dated Dec 13, 2023 Not yet checked
Warranty, at p.2 / s.3 Product Warranty, p.2 / s.4.1 table, retrieved Sep 25, 2026, dated Dec 13, 2023 Not yet checked

The stated 54 MWh equals 3,375 full cycles of its 16 kWh usable energy.

Compare warranties.

Features the manufacturer states

LG RESU16H Prime: stated features
FeatureStatedSource
Built-in inverter No Not yet checked Web page, at p.2 / Compatible storage Inverters with Prime [US], retrieved Sep 25, 2026, dated May 12, 2025
Compatible inverters US list: SBS3.8/5.0/6.0-US, GW*A-ES, GW*A-BP, GW*SBP-US20, MIN *TL-XH-US, GEH/GEC*-1U-US10, SHB-G1-096-US, E4/E6/E8/E10-TL-US, S6-EH1P*-H-US, D007KEEN261 Not yet checked Web page, at pp.2–3 / Compatible storage Inverters with Prime [US], retrieved Sep 25, 2026, dated May 12, 2025
Enclosure rating IP55 Checked against the document Spec sheet, at p.2 / Certification, retrieved Sep 25, 2026Ingress Rating IP55
Dimensions 504 x 1086 x 295 mm Checked against the document Spec sheet, at p.3 / Mechanical Characteristics, retrieved Sep 25, 2026Width 19.8 inch (504 mm) Height 42.8 inch (1086 mm) Depth 11.6 inch (295 mm)
Product status current Not yet checked Web page, at US Home Battery product-info page, retrieved Sep 25, 2026

Government and program lists

This product is on none of the lists this site reads.

Installs

No install count this site publishes covers this product.

Recalls and safety notices

No notice in the recall sources this site reads is matched to this product. That is not a safety finding. See every recall notice.

  • UL 9540 listed: Yes as a system with a UL 1741 inverter
    Web page, at p.2 / note, retrieved Sep 25, 2026, dated May 12, 2025 Not yet checked

The maker states the listing or test. The listing body's records have not been checked.

Backup hours from your load

Appliance nameplate maximums

The stated usable energy divided by your load gives hours, starting with a full battery.

Spec sheet, at p.2 / Electrical Characteristics, retrieved Sep 25, 2026Usable Energy1) 16.0 kWh @77°F (25°C)
Spec sheet, at p2, Electrical Characteristics, retrieved Sep 23, 2026 Not yet checked

Continuous power: 7 kW (DC)

Peak power: 11 kW (DC, discharging, for 10 sec.)

Backup hours follow the California Air Resources Board’s Zero Emissions Residential Backup Power Tool. Appliance figures come from the US Department of Energy’s Estimating Appliance and Home Electronic Energy Use (2012).

  • The appliance figures are nameplate maximums. Average demand changes as appliances cycle and their settings change.
  • A load above the stated continuous power gets no figure.
  • Motor starts use three times the largest selected motor’s watts, plus the other loads. This estimate is checked against stated peak power when available. Other loads are counted at their running watts.
  • Its 7 kW is stated on the DC side. The paired inverter’s AC rating can be lower and is not in this calculation.
  • Inverter and battery losses are not counted. A field study of household backup power explains the gap.
  • Solar recharge, reserves, and temperature changes are outside the calculation.

Download this battery’s figures as JSON