sonnenCore+

sonnen states 10 kWh (sonnenCore+ (SCORE-P10), United States) to 20 kWh (sonnenCore+ (SCORE-P20), United States) usable energy.

sonnen states 9.6 kVA (sonnenCore+ (2 units), United States, AC, grid-tied output at 104°F) to 14.4 kVA (sonnenCore+ (3 units), United States, AC, grid-tied output at 104°F) continuous apparent power.

Warranty terms: 10 years (United States); warranted throughput: 85 MWh (sonnenCore+ (SCORE-P10, 10 kWh), United States); warranted throughput: 170 MWh (sonnenCore+ (SCORE-P20, 20 kWh), United States); warranted throughput: 181 MWh (sonnenCore+ (20 kWh)); warranted cycles: 10,000 cycles (United States); capacity at warranty end: 70% (United States).

Brand: sonnen

Published figures

No figures have been collected for motor-start current.

sonnenCore+: 12 published figures
FigureValuePublisherSource
Usable energy, sonnenCore+ (SCORE-P10) 10 kWh Manufacturer Not yet checked Spec sheet, at p.1 Stacked specifications, retrieved Sep 23, 2026, dated Nov 18, 2024
Usable energy, sonnenCore+ (SCORE-P20) 20 kWh Manufacturer Not yet checked Spec sheet, at p.1 Stacked specifications, retrieved Sep 23, 2026, dated Nov 18, 2024
Continuous power, sonnenCore+ (1 unit) (AC, grid-tied output at 104°F) 4.8 kVA Manufacturer Not yet checked Spec sheet, at p1, Stacked specifications, retrieved Sep 23, 2026, dated Nov 18, 2024
Continuous power, sonnenCore+ (2 units) (AC, grid-tied output at 104°F) 9.6 kVA Manufacturer Not yet checked Spec sheet, at p.1 Stacked specifications / Nominal power rating, retrieved Sep 23, 2026, dated Nov 18, 2024
Continuous power, sonnenCore+ (3 units) (AC, grid-tied output at 104°F) 14.4 kVA Manufacturer Not yet checked Spec sheet, at p.1 Stacked specifications / Nominal power rating, retrieved Sep 23, 2026, dated Nov 18, 2024
Round-trip efficiency 85.4% Manufacturer Not yet checked Spec sheet, at p1, Stacked specifications, retrieved Sep 23, 2026, dated Nov 18, 2024
Units per system 3 units Manufacturer Not yet checked Spec sheet, at p.1 Stacked specifications, retrieved Sep 23, 2026, dated Nov 18, 2024
Largest stack 60 kWh Manufacturer Not yet checked Spec sheet, at p.1 intro / Stacked specifications, retrieved Sep 23, 2026, dated Nov 18, 2024
Lowest operating temperature 0°C Manufacturer Not yet checked Spec sheet, at p1, General, retrieved Sep 23, 2026, dated Nov 18, 2024
Highest operating temperature 45°C Manufacturer Not yet checked Spec sheet, at p1, General, retrieved Sep 23, 2026, dated Nov 18, 2024
Weight, sonnenCore+ (SCORE-P10) 160 kg Manufacturer Not yet checked Spec sheet, at p.1 Weight per unit, retrieved Sep 23, 2026, dated Nov 18, 2024
Weight, sonnenCore+ (SCORE-P20) 238 kg Manufacturer Not yet checked Spec sheet, at p.1 Weight per unit, retrieved Sep 23, 2026, dated Nov 18, 2024

Stated stack range

Largest stated stack: 60 kWh (energy basis not stated) (3 units).

Spec sheet, at p.1 intro / Stacked specifications, p.1 Stacked specifications, retrieved Sep 23, 2026, dated Nov 18, 2024 Not yet checked

Compare stated stack ranges.

Stated temperature limits

Stated operating range: 32°F (0°C) to 113°F (45°C).

Spec sheet, at p1, General, retrieved Sep 23, 2026, dated Nov 18, 2024 Not yet checked

Compare temperature limits.

After you enter a ZIP code, day counts describe outdoor air at the nearest station. A garage or indoor unit sees different air from the station. Output reductions inside the stated range are not counted.

Warranty terms

sonnenCore+ warranty terms
TermFigureDocument
Warranty, United States10 yearsWarranty, at p2 header / p3 Sec. 4 table, retrieved Sep 23, 2026, dated Nov 18, 2025
Warranted throughput, United StatessonnenCore+ (SCORE-P10, 10 kWh): 85 MWhWarranty, at p3, Sec. 4, retrieved Sep 23, 2026, dated Nov 18, 2025
Warranted throughput, United StatessonnenCore+ (SCORE-P20, 20 kWh): 170 MWhWarranty, at p3, Sec. 4, retrieved Sep 23, 2026, dated Nov 18, 2025
Warranted throughputsonnenCore+ (20 kWh): 181 MWhSpec sheet, at product page body, retrieved Sep 23, 2026, dated Sep 23, 2026
Warranted cycles, United States10,000 cyclesWarranty, at p10, Sec. 7(g), retrieved Sep 23, 2026, dated Nov 18, 2025
Capacity at warranty end, United States70%Warranty, at p3, Sec. 4, retrieved Sep 23, 2026, dated Nov 18, 2025 page cited, no quote
Warranty, at p2 header / p3 Sec. 4 table, p3, Sec. 4, p10, Sec. 7(g), retrieved Sep 23, 2026, dated Nov 18, 2025 Not yet checked
Spec sheet, at product page body, retrieved Sep 23, 2026, dated Sep 23, 2026 Not yet checked

Compare warranties.

Features the manufacturer states

sonnenCore+: stated features
FeatureStatedSource
Chemistry LFP Not yet checked Spec sheet, at p2, Battery specification, retrieved Sep 23, 2026, dated Nov 18, 2024
Coupling AC Not yet checked Spec sheet, at p.1 Grid integration, retrieved Sep 23, 2026, dated Nov 18, 2024
Backup Emergency backup, off-grid 25 A RMS continuous per unit (50 A / 75 A for 2 / 3 units), 36 A for 5 s, 200 A on-grid pass-through with AC Connections module (2-3 units) Not yet checked Spec sheet, at p.1 Off-grid specifications, retrieved Sep 23, 2026, dated Nov 18, 2024
Built-in inverter Yes Not yet checked Spec sheet, at p.2 Warranty, retrieved Sep 23, 2026, dated Nov 18, 2024
Enclosure rating IP30 Not yet checked Spec sheet, at p.2 Compliance information, retrieved Sep 23, 2026, dated Nov 18, 2024
Nominal battery voltage 102 V Not yet checked Spec sheet, at p.2 Battery specification, retrieved Sep 23, 2026, dated Nov 18, 2024
Dimensions 689.9 x 1607.3 x 351.8 (W x H x D) mm Not yet checked Spec sheet, at p.2 Dimensions drawing, retrieved Sep 23, 2026, dated Nov 18, 2024
Product status current Not yet checked Warranty, at product list in header, retrieved Sep 25, 2026, dated Nov 25, 2025

Government and program lists

This product is on none of the lists this site reads.

Installs

No install count this site publishes covers this product.

Recalls and safety notices

No notice in the recall sources this site reads is matched to this product. That is not a safety finding. See every recall notice.

  • UL 9540 listed: Yes
    Spec sheet, at p.2 Compliance information / Certifications, retrieved Sep 23, 2026, dated Nov 18, 2024 Not yet checked
  • UL 9540A tested: Yes
    Spec sheet, at p.2 Compliance information / Certifications, retrieved Sep 23, 2026, dated Nov 18, 2024 Not yet checked

The maker states the listing or test. The listing body's records have not been checked.

Backup hours from your load

Its continuous power is stated in kVA, the inverter’s volt-ampere rating, not in kW, so no backup hours are calculated.