Home Battery List

Enphase IQ Battery 10T

Enphase states 10.08 kWh usable energy (Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA), United States) and 10.5 kWh nominal energy (Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA), United States).

Enphase states 3.84 kVA continuous apparent power (Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA), United States, AC).

Warranty terms: 15 years (Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA), United States); warranted cycles: 6,000 cycles (Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA), United States); capacity at warranty end: 60% (Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA), United States).

Brand: Enphase

Published figures

No figures have been collected for motor-start current, units per system, and warranty throughput.

Enphase IQ Battery 10T: 8 published figures
FigureValuePublisherSource
Usable energy, Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA) 10.08 kWh Manufacturer Not yet checked Spec sheet, at p.2 / BATTERY, retrieved Sep 25, 2026, dated Apr 9, 2024
Nominal energy, Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA) 10.5 kWh Manufacturer Not yet checked Spec sheet, at p.2 / BATTERY, retrieved Sep 25, 2026, dated Apr 9, 2024
Continuous power, Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA) (AC) 3.84 kVA Manufacturer Not yet checked Spec sheet, at p.2 / OUTPUT (AC) @ 240 VAC, retrieved Sep 25, 2026, dated Apr 9, 2024
Peak power, Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA) (AC, 10 seconds) 5.76 kVA Manufacturer Not yet checked Spec sheet, at p.2 / OUTPUT (AC) @ 240 VAC, retrieved Sep 25, 2026, dated Apr 9, 2024
Round-trip efficiency, United States, Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA) 89% Manufacturer Not yet checked Spec sheet, at p.2 / OUTPUT (AC), retrieved Sep 25, 2026, dated Apr 9, 2024
Lowest operating temperature, Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA) −15°C Manufacturer Not yet checked Spec sheet, at p.2 / BATTERY, retrieved Sep 25, 2026, dated Apr 9, 2024
Highest operating temperature, Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA) 55°C Manufacturer Not yet checked Spec sheet, at p.2 / BATTERY, retrieved Sep 25, 2026, dated Apr 9, 2024
Weight, Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA) 143.6 kg Manufacturer Not yet checked Spec sheet, at p.2 / MECHANICAL DATA, retrieved Sep 25, 2026, dated Apr 9, 2024

See it on the home battery chart

Usable and nominal energy

Nominal energy is the stated total stored energy. Usable energy is the stated amount available to draw.

Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA): Enphase IQ Battery 10T states 10.08 kWh usable and 10.5 kWh nominal energy (96% usable).

Spec sheet, at p.2 / BATTERY, retrieved Sep 25, 2026, dated Apr 9, 2024 Not yet checked

Compare usable and nominal energy.

Stated temperature limits

Stated operating range: 5°F (−15°C) to 131°F (55°C), Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA).

Spec sheet, at p.2 / BATTERY, retrieved Sep 25, 2026, dated Apr 9, 2024 Not yet checked

Compare temperature limits.

After you enter a ZIP code, day counts describe outdoor air at the nearest station. A garage or indoor unit sees different air from the station. Output reductions inside the stated range are not counted.

Warranty terms

Enphase IQ Battery 10T warranty terms
TermFigureDocument
Warranty, United StatesEnphase IQ Battery 10T (ENCHARGE-10T-1P-NA): 15 yearsWarranty, at p.1 / s.1 table (IQ Battery 3T/10T), retrieved Sep 25, 2026, dated Jul 1, 2023
Warranted cycles, United StatesEnphase IQ Battery 10T (ENCHARGE-10T-1P-NA): 6,000 cyclesWarranty, at p.1 / s.1 table (IQ Battery 3T/10T), retrieved Sep 25, 2026, dated Jul 1, 2023
Capacity at warranty end, United StatesEnphase IQ Battery 10T (ENCHARGE-10T-1P-NA): 60%Warranty, at p.1 / s.3.a, retrieved Sep 25, 2026, dated Jul 1, 2023
Warranty, at p.1 / s.1 table (IQ Battery 3T/10T), p.1 / s.3.a, retrieved Sep 25, 2026, dated Jul 1, 2023 Not yet checked

Compare warranties.

Features the manufacturer states

Configuration: Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA).

Enphase IQ Battery 10T: stated features
FeatureStatedSource
Chemistry LFP Not yet checked Spec sheet, at p.2 / BATTERY, retrieved Sep 25, 2026, dated Apr 9, 2024
Coupling AC Not yet checked Spec sheet, at p.1 / intro, retrieved Sep 25, 2026, dated Apr 9, 2024
Whole-home backup Yes Checked against the document Manual, at p.11 / Whole home backup, retrieved Sep 25, 2026Whole home backup is ideal for homeowners who want all-day whole home backup power for running appliances during a grid outage.
Backup grid-forming backup via IQ System Controller Not yet checked Spec sheet, at p.1 / Smart, retrieved Sep 25, 2026, dated Apr 9, 2024
Built-in inverter Yes Not yet checked Spec sheet, at p.1 / Simple, retrieved Sep 25, 2026, dated Apr 9, 2024
Compatible inverters M215/M250 and IQ Series microinverters Not yet checked Spec sheet, at p.2 / FEATURES AND COMPLIANCE, retrieved Sep 25, 2026, dated Apr 9, 2024
Enclosure rating NEMA 3R Not yet checked Spec sheet, at p.2 / MECHANICAL DATA, retrieved Sep 25, 2026, dated Apr 9, 2024
Nominal battery voltage 67.2 V Not yet checked Spec sheet, at p.2 / BATTERY, retrieved Sep 25, 2026, dated Apr 9, 2024
Grid voltage 240 V AC Not yet checked Spec sheet, at p.2 / OUTPUT (AC), retrieved Sep 25, 2026, dated Apr 9, 2024
Dimensions 1283 x 775 x 188 mm Not yet checked Spec sheet, at p.2 / MECHANICAL DATA, retrieved Sep 25, 2026, dated Apr 9, 2024

Government and program lists

This product is on none of the lists this site reads.

Installs

No install count this site publishes covers this product.

Recalls and safety notices

No notice in the recall sources this site reads is matched to this product. That is not a safety finding. See every recall notice.

  • UL 9540 listed: Yes (Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA))
    Spec sheet, at p.2 / Compliance, retrieved Sep 25, 2026, dated Apr 9, 2024 Not yet checked
  • UL 9540A tested: Yes (Enphase IQ Battery 10T (ENCHARGE-10T-1P-NA))
    Spec sheet, at p.2 / Compliance, retrieved Sep 25, 2026, dated Apr 9, 2024 Not yet checked

The maker states the listing or test. The listing body's records have not been checked.

Backup hours from your load

Its continuous power is stated in kVA, the inverter’s volt-ampere rating, not in kW, so no backup hours are calculated.

Download this battery’s figures as JSON