Tesla Powerwall 2
Tesla states 13.5 kWh usable energy (United States) and 14 kWh nominal energy (United States).
Tesla states 5 kW continuous power (United States, AC).
Warranty terms: 10 years (United States); warranted throughput: 37.8 MWh (United States, only applications outside solar self-consumption, time-based control and backup); capacity at warranty end: 70% (United States).
Tesla Powerwall 2 was included in the recall notice “Tesla Recalls Powerwall 2 AC Battery Power Systems Due to Fire and Burn Hazards; Risk of Serious Injury or Death” on Nov 13, 2025 (recall date).
Recalls: CPSC Nov 13, 2025 and ACCC Sep 16, 2025Brand: Tesla
Product history
Tesla Powerwall 2 was included in the recall notice “Tesla Recalls Powerwall 2 AC Battery Power Systems Due to Fire and Burn Hazards; Risk of Serious Injury or Death” on Nov 13, 2025 (recall date).
Tesla Powerwall 2 was included in the recall notice “Powerwall 2” on Sep 16, 2025 (recall date).
Published figures
No figures have been collected for units per system.
| Figure | Value | Publisher | Source |
|---|---|---|---|
| Usable energy | 13.5 kWh | Manufacturer Not yet checked | Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Nominal energy | 14 kWh | Manufacturer Not yet checked | Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Continuous power (AC) | 5 kW | Manufacturer Not yet checked | Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Peak power (AC) | 7 kW | Manufacturer Not yet checked | Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Motor start (LRA) | 88–106 A | Manufacturer Not yet checked | Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Round-trip efficiency, United States | 90% | Manufacturer Not yet checked | Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Lowest operating temperature | −20°C | Manufacturer Not yet checked | Spec sheet, at p.1 / ENVIRONMENTAL SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Highest operating temperature | 50°C | Manufacturer Not yet checked | Spec sheet, at p.1 / ENVIRONMENTAL SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Weight | 114 kg | Manufacturer Not yet checked | Spec sheet, at p.1 / MECHANICAL SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
See it on the home battery chart
Usable and nominal energy
Nominal energy is the stated total stored energy. Usable energy is the stated amount available to draw.
Tesla Powerwall 2 states 13.5 kWh usable and 14 kWh nominal energy (96% usable).
Stated temperature limits
Stated operating range: −4°F (−20°C) to 122°F (50°C).
Battery’s stated motor-start current: 88–106 A (LRA means locked-rotor amps, a motor’s starting current). Compare starting current.
Warranty terms
| Term | Figure | Document |
|---|---|---|
| Warranty, United States | 10 years | Warranty, at p.1 / Ten Year Limited Warranty, retrieved Sep 23, 2026, dated May 6, 2026 |
| Warranted throughput, United States | 37.8 MWh (only applications outside solar self-consumption, time-based control and backup) | Warranty, at p.1 / Energy Retention table, row 2, retrieved Sep 23, 2026, dated May 6, 2026 |
| Capacity at warranty end, United States | 70% | Warranty, at p.1 / Energy Retention table, retrieved Sep 23, 2026, dated May 6, 2026 |
Features the manufacturer states
| Feature | Stated | Source |
|---|---|---|
| Chemistry | lithium-ion Not yet checked | Spec sheet, at p.1 / intro paragraph, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Coupling | AC Not yet checked | Spec sheet, at p.1 / intro, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Whole-home backup | Yes Not yet checked | Manual, at p.8 / Whole Home Backup System, retrieved Sep 25, 2026 |
| Backup | partial or whole home backup via Backup Gateway Not yet checked | Manual, at p.7–8 / System Design, retrieved Sep 25, 2026 |
| Enclosure rating | NEMA 3R, IP67 (battery & power electronics), IP56 (wiring compartment) Not yet checked | Spec sheet, at p.1 / ENVIRONMENTAL SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Nominal battery voltage | 50 V Not yet checked | Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Grid voltage | 120/240 V AC Not yet checked | Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
| Dimensions | 1150 x 753 x 147 mm Not yet checked | Spec sheet, at p.1 / MECHANICAL SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 |
Configurations
Part numbers not named by these figures
- Powerwall 2 AC, part 1092170
- Powerwall 2 AC, part 2012170
- Powerwall 2 AC, part 3012170
Government and program lists
This product is on none of the lists this site reads.
Installs
Medians require at least 20 priced installs for the named measure and period.
- Connecticut records 1 install, approval year unavailable. Source: Connecticut Energy Storage Solutions — enrollment. No median battery cost per kWh: 1 priced install (approval year unavailable).
What Connecticut homes paid
All recorded installs were paired with solar PV.
All years includes 1 install with no recorded approval year.
Figures are medians. Parentheses give the middle half of prices. A dash means too few prices for a median.
| Year | Pairing | Installs | Battery cost per kWh | Total battery cost | Contract price | Up-front incentive |
|---|---|---|---|---|---|---|
| All years | Paired with solar PV | 11 with no approval year | —1 priced install, Approval year unavailable | —1 priced install, Approval year unavailable | —1 priced install, Approval year unavailable | —0 priced installs |
Contract prices may include solar or other equipment. Prices are before the up-front incentive. Approvals run through Sep 29, 2026. Counts and prices are from the program’s Oct 1, 2026 release.
Recalls and safety notices
- , CPSC: Tesla Recalls Powerwall 2 AC Battery Power Systems Due to Fire and Burn Hazards; Risk of Serious Injury or Death
CPSC, Nov 13, 2025:
Hazard: The lithium-ion battery cells in certain Powerwall 2 systems can cause the unit to stop functioning during normal use, which can result in overheating and, in some cases, smoke or flame and can cause death or serious injury due to fire and burn hazards.
Remedy: Consumers should ensure their Powerwall 2 system is online and check the Tesla App for a notification about whether their unit is included in the recall. Tesla has remotely discharged (or removed energy from the battery of) affected Powerwall 2 systems that are online, to prevent overheating, until the replacement is installed.
- , ACCC: Powerwall 2
ACCC, Sep 16, 2025. Notice summary:
Hazard: Certain third-party lithium-ion battery cells in a subset of Powerwall 2 systems may fail and overheat. Reports of smoking or flames with minor property damage.
Remedy: Free replacement. Tesla remotely discharges affected online units. Compensation for lost energy savings considered case by case.
- UL 9540 listed: YesSpec sheet, at p.1 / COMPLIANCE INFORMATION, retrieved Sep 23, 2026, dated Jul 2, 2024 Not yet checked
- UL 9540A tested: YesSpec sheet, at p.1 / COMPLIANCE INFORMATION, retrieved Sep 23, 2026, dated Jul 2, 2024 Not yet checked
The maker states the listing or test. The listing body's records have not been checked.
Backup hours from your load
The stated usable energy divided by your load gives hours, starting with a full battery.
The spec sheet states its usable energy at 25°C.
Continuous power: 5 kW (AC)
Peak power: 7 kW (AC)
Backup hours follow the California Air Resources Board’s Zero Emissions Residential Backup Power Tool. Appliance figures come from the US Department of Energy’s Estimating Appliance and Home Electronic Energy Use (2012).
- The appliance figures are nameplate maximums. Average demand changes as appliances cycle and their settings change.
- A load above the stated continuous power gets no figure.
- Motor starts use three times the largest selected motor’s watts, plus the other loads. This estimate is checked against stated peak power when available. Other loads are counted at their running watts.
- Inverter and battery losses are not counted. A field study of household backup power explains the gap.
- Solar recharge, reserves, and temperature changes are outside the calculation.