Home Battery List

Tesla Powerwall 2 and Powerwall 3, side by side

Tesla Powerwall 2 and Tesla Powerwall 3: published usable energy, continuous power, warranty and recalls, each figure with its source.

Stated figures, side by side
FigureTesla Powerwall 2Recalls: CPSC Nov 13, 2025 and ACCC Sep 16, 2025Tesla Powerwall 3
Usable energy (kWh)13.5
Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 Not yet checked
13.5
Japanese ZEH list (SII), retrieved Oct 23, 2026
Nominal energy (kWh)14
Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 Not yet checked
13.5
Spec sheet, at p.2 / System Technical Specifications, retrieved Sep 23, 2026 Not yet checked
Continuous power (kW)5
Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 Not yet checked
5.8–11.55.8: AC, grid-code output setting, one of four7.6: AC, grid-code output setting, one of four10: AC, grid-code output setting, one of four11.5: AC, grid-code output setting, one of four
Spec sheet, at p.2 / System Technical Specifications, retrieved Sep 23, 2026 Not yet checked
Peak power (kW)7
Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 Not yet checked
—
Motor start (LRA) (A)88–106
Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 Not yet checked
185
Spec sheet, at p.2 / System Technical Specifications, retrieved Sep 23, 2026 Not yet checked
Round-trip efficiency (%)90
Spec sheet, at p.1 / PERFORMANCE SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 Not yet checked
—
Warranty (years)10
Warranty, at p.1 / Ten Year Limited Warranty, retrieved Sep 23, 2026, dated May 6, 2026 Not yet checked
10
Warranty, at p.1 / Ten Year Limited Warranty, retrieved Sep 23, 2026, dated May 6, 2026 Not yet checked
Warranted throughput (MWh)37.837.8: only applications outside solar self-consumption, time-based control and backup
Warranty, at p.1 / Energy Retention table, row 2, retrieved Sep 23, 2026, dated May 6, 2026 Not yet checked
37.837.8: only applications outside solar self-consumption, time-based control and backup
Warranty, at p.1 / Energy Retention table, row 2, retrieved Sep 23, 2026, dated May 6, 2026 Not yet checked
Capacity at warranty end (%)70
Warranty, at p.1 / Energy Retention table, retrieved Sep 23, 2026, dated May 6, 2026 Not yet checked
70
Warranty, at p.1 / Energy Retention table, retrieved Sep 23, 2026, dated May 6, 2026 Not yet checked
Chemistrylithium-ion
Spec sheet, at p.1 / intro paragraph, retrieved Sep 23, 2026, dated Jul 2, 2024 Not yet checked
—
CouplingAC
Spec sheet, at p.1 / intro, retrieved Sep 23, 2026, dated Jul 2, 2024 Not yet checked
AC or DC
Web page, at Design Considerations / Compatibility table, retrieved Sep 25, 2026 Not yet checked
Whole-home backupYes
Manual, at p.8 / Whole Home Backup System, retrieved Sep 25, 2026 Not yet checked
Yes
Manual, at p.8 / Whole Home Backup System, retrieved Sep 25, 2026 Not yet checked
Units per system—77: up to 4 Powerwall 3 + 3 Expansions
Spec sheet, at p.2 / System Technical Specifications, retrieved Sep 23, 2026 Not yet checked
Lowest operating temperature (°C)−20
Spec sheet, at p.1 / ENVIRONMENTAL SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 Not yet checked
−20
Spec sheet, at p.3 / Environmental Specifications, retrieved Sep 23, 2026 Not yet checked
Highest operating temperature (°C)50
Spec sheet, at p.1 / ENVIRONMENTAL SPECIFICATIONS, retrieved Sep 23, 2026, dated Jul 2, 2024 Not yet checked
50
Spec sheet, at p.3 / Environmental Specifications, retrieved Sep 23, 2026 Not yet checked
Recall noticesRecalls: CPSC Nov 13, 2025 and ACCC Sep 16, 2025

CPSC, Nov 13, 2025:

Hazard: The lithium-ion battery cells in certain Powerwall 2 systems can cause the unit to stop functioning during normal use, which can result in overheating and, in some cases, smoke or flame and can cause death or serious injury due to fire and burn hazards.

Remedy: Consumers should ensure their Powerwall 2 system is online and check the Tesla App for a notification about whether their unit is included in the recall. Tesla has remotely discharged (or removed energy from the battery of) affected Powerwall 2 systems that are online, to prevent overheating, until the replacement is installed.

ACCC, Sep 16, 2025. Notice summary:

Hazard: Certain third-party lithium-ion battery cells in a subset of Powerwall 2 systems may fail and overheat. Reports of smoking or flames with minor property damage.

Remedy: Free replacement. Tesla remotely discharges affected online units. Compensation for lost energy savings considered case by case.

No matched notice

See these batteries on the comparison chart

Choose other batteries

Limits

A dash means no figure for it is in the documents cited here. Power stated in kVA (apparent power, the inverter’s volt-ampere rating) is not compared with kW. Tesla documents may state figures for different configurations.

How these figures are compared